Our site saves small pieces of text information (cookies) on your device in order to deliver better content and for statistical purposes. You can disable the usage of cookies by changing the settings of your browser. By browsing our site without changing the browser settings you grant us permission to store that information on your device.

Axial strain based Bragg grating level sensor

D. SENGUPTA1, M. SAI SHANKAR1,* , P. SAIDI REDDY1, R. L. N SAI PRASAD1, K. SRIMANNARAYANA1

Affiliation

  1. Department of Physics, National Institute of Technology, Waranagal-506 004, India

Abstract

Design and construction of a liquid level sensor using FBG, based on change in axial strain due buoyancy is presented. The lever in the system induces axial strain on the FBG due to change in level, resulting in modulation of the Bragg wavelength. The shift in the Bragg wavelength is a measure of change in liquid level. The Bragg grating (3 mm length) used in this work has been fabricated using a phase mask technique and written in a photosensitive optical fiber. A sensitivity of 0.106 nm/cm is observed for a level change of 13 cm. The results obtained indicate that the sensor has good sensitivity and repeatability. The sensor can be customized for a required level measurement for a particular application.

Keywords

Axial strain, Buoyancy, Fiber Bragg grating, Liquid-level sensor.

Citation

D. SENGUPTA, M. SAI SHANKAR, P. SAIDI REDDY, R. L. N SAI PRASAD, K. SRIMANNARAYANA, Axial strain based Bragg grating level sensor, Optoelectronics and Advanced Materials - Rapid Communications, 4, 12, December 2010, pp.1933-1936 (2010).

Submitted at: Oct. 29, 2010

Accepted at: Nov. 29, 2010