Our site saves small pieces of text information (cookies) on your device in order to deliver better content and for statistical purposes. You can disable the usage of cookies by changing the settings of your browser. By browsing our site without changing the browser settings you grant us permission to store that information on your device.

Critical magnetic field analysis of porous foam magnetorheological (MR) fluid damper

LIU X. HU1,* , H. ZHANG1, GAO X. LI1, YAO X. YAN1, SUN MENG1

Affiliation

  1. School of Mechanical Engineering, Shanghai Institute of Technology, Shanghai 201418, China

Abstract

In this paper, a new porous foam magntrorheological (MR) fluid damper is proposed. In the action of magnetic field, the metal foam is used to store and release the MR fluids. It is worthy to study the time MR fluids can be extracted and produce damping force. Therefore, the critical magnetic field intensity is investigated experimentally by a custom-made test rig. The experimental results show that when magnetic field intensity increased to a critical value, the MR fluids are extracted out from the porous foam into shear gap, and move with the piston, the shear damping force begin to change..

Keywords

Critical magnetic field, Magnetorheological (MR) fluid, MR damper, Porous foam.

Citation

LIU X. HU, H. ZHANG, GAO X. LI, YAO X. YAN, SUN MENG, Critical magnetic field analysis of porous foam magnetorheological (MR) fluid damper, Optoelectronics and Advanced Materials - Rapid Communications, 10, 1-2, January-February 2016, pp.74-77 (2016).

Submitted at: Oct. 22, 2013

Accepted at: Feb. 10, 2016