Abstract
This work evaluated the Hp(10)dose for the personnel exposed in mixed field inside several locations of reactor 1 building
at Cernavoda NPP. In order to achieve this we used active (EPD N2 and DMC 2000GN) and passive (TLD 8806) personnel
dosimeters and one ambient neutron monitor for H*(10) evaluation. The dose correction coefficients vary from one room to
another depending on the neutron spectra. The obtained values range from 1.6 to 4 meaning that all dosimeters are over
evaluating the exposure..
Keywords
Thermoluminescent Neutron Dosimeter, neutron field correction coefficient, personnel dose evaluation.
Citation
D. DUMITRESCU, A. CHIROSCA, Neutron field correction coefficients for active and passive dosimeters in Cernavoda NPP, Optoelectronics and Advanced Materials - Rapid Communications, 5, 6, June 2011, pp.690-695 (2011).