Our site saves small pieces of text information (cookies) on your device in order to deliver better content and for statistical purposes. You can disable the usage of cookies by changing the settings of your browser. By browsing our site without changing the browser settings you grant us permission to store that information on your device.

Neutron field correction coefficients for active and passive dosimeters in Cernavoda NPP

D. DUMITRESCU1,2,* , A. CHIROSCA2

Affiliation

  1. Cernavoda Nuclear Power Plant, 2, Medgidia str., Cernavoda 905200, Romania
  2. University of Bucharest, Department of Atomic and Nuclear Physics, P.O. Box MG-11, 077125 Magurele (Ilfov), Romania

Abstract

This work evaluated the Hp(10)dose for the personnel exposed in mixed field inside several locations of reactor 1 building at Cernavoda NPP. In order to achieve this we used active (EPD N2 and DMC 2000GN) and passive (TLD 8806) personnel dosimeters and one ambient neutron monitor for H*(10) evaluation. The dose correction coefficients vary from one room to another depending on the neutron spectra. The obtained values range from 1.6 to 4 meaning that all dosimeters are over evaluating the exposure..

Keywords

Thermoluminescent Neutron Dosimeter, neutron field correction coefficient, personnel dose evaluation.

Citation

D. DUMITRESCU, A. CHIROSCA, Neutron field correction coefficients for active and passive dosimeters in Cernavoda NPP, Optoelectronics and Advanced Materials - Rapid Communications, 5, 6, June 2011, pp.690-695 (2011).